external AED defibrillator monitor
Standard Parameters | ||||||
NIBP | ETCO2 | AED | PACER | PRINTER | ECG | SPO2 |
Screen Type: High-resolution display
Screen Size: 8 inch
Languages: 5toChoose
Sweep Speed: 25mm/sec
Information: Heart Rate.Lead/Pads.Alarm On/OffSp2 AED Functions and Prompts Alarm Selection and Limits Delivered Energy
1. Turn on: Place the AED next to the patient and operate on the patient's side. To turn on the AED, press the power switch or open the cover of the display. The instrument will give a voice prompt to guide the next steps.
2. Paste: Place the electrode pads.
1) Adult electrode pad placement: According to the diagram on the AED electrode pad, stick one electrode pad on the upper right side of the patient's exposed chest and the other electrode pad on the outside of the patient's left nipple.
2) Infant and child electrode pad placement: Stick the two electrode pads on the center of the chest and the left shoulder blade behind the infant and child respectively. Larger children can also place the electrode pads in the same position as adults.
3. Plug: Insert the electrode pad plug into the AED host jack, and the AED will automatically analyze the heart rate. At this time, emergency personnel and bystanders should ensure that they do not come into contact with the patient to avoid affecting the instrument's analysis of the heart rate. Heart rhythm analysis takes 5 to 15 seconds.
4. Charge: When the AED analyzes a heart rhythm that requires defibrillation, the capacitor will often charge automatically, and there will be a sound or indicator light prompt. Before pressing the "shock" button, make sure that no one is touching the patient. After the first shock, immediately continue cardiopulmonary resuscitation (CPR).
Standard equipment | |
EKG Cable (5 Leads) | 1Pcs |
AED Pad connector | 1Pcs |
AED Pad | 1Pcs |
Ground Cable | 1Pcs |
Power Cable | 1Pcs |
Thermal Paper Role | 1Pcs |
Cleaning Cloth | 1Pcs |
Optional equipment | |
ECG Cable | Adult/ pediatric/ neonate hard soft/ hard/ shell sensor |
ECG Alligator Clips | Adult/ pediatric/ neonate |
SpO2 Cable | Adult/ pediatric/ neonate |
NIBP Cuff | Adult/ pediatric/ neonate |
NIBP Tube 150cm | Adult/ pediatric/ neonate |
Paper Role, Thermal printer, Defibrillator Wall mounts, Defibrillator Trolley | |
MOQ | 1 |
Payment | TT, Western union, Credit card |
Shipping | Express, sea, plane |
SpO2 Module (Options)
1.Measurement range:30~100%±2% between80%~90% other ±5%
2.Alarm range: user defined upper and lower limit.
3.Alarm accuracy: ±10% within the set values.
4.Alarm time accuracy: less than 12 sec.
5.Pulse Oximeter
Recorder
1.Paper: 50mm thermal.
2.Speed:12.5mm/sec.25mm/sec.50mm/sec.
User selectable delay of 6 seconds.
3.Printing method: High resolution thermal print head.
4.Print Modes: Manual or automatic, user configurable.
5.On/off control: front panel and paddle.
6.Automatic function: 9-second recording triggered by alarm activation,
7.defibrillator charge or defibrillator discharge.
1.CO2 range 0 to 13%(0-98.8mmHg@BTPS)
2.CO2 accuracy <5.0% CO2 (for BTPS) ± 3 mmHg ;
>5.0% CO2 (at BTPS)< 10% of reading
3.Respiratory rate 3~60 BPM Measurement accuracy ±1BPM
Manual Mode
1.Energy selection: Selectable at 2 5 7 10 20 30 50 70 100 150 200 300 360 joules.
2.Synchronized mode: Synchronizes the defibrillator pulse with the R-wave.
3.The message "SYNC" is displayed on the monitor.
NIBP(Options)
1.Method: automatic oscillation
2.Working mode: manual/automatic
3.Measure: adult: 10-250mmHg
4.Ement: pediatric: 10-200mmHg
5.Ement: neonatal: 10-135mmHg
AED Mode
AED function: automatic analysis and charging x3 with programmable automatic energy level selection, on-screen prompts and voice prompts.
Shock capable rhythms: Ventricular fibrillation
with amplitude> =200uV Ventricular tachycardia
with rates > =140bpm and QRS complex
wave duration>=140ms.
Charge control: front panel,
push button on paddle.
Prompts: Voice and visual prompts.
Pacemaker (Options)
1.Type: VVI
2.Pulse type: rectangular, constant current
3.Pulse amplitude: 0 to 180 mA±10% or 5 mA (whichever is greater).
4.Pacing frequency: Variable from 30 ppm to 180 ppm ±1.5% (increments or decrements by a value of 2 ppm)
5.Multifunctional Electrode:(MFE) Pads: multipurpose defibrillation/pacing electrodes
6.Pause: pacing pulse rate is reduced by a factor of 4 upon activation
7.Refractory period: NC (VVI requirements do not have this specification)
8.Pulse width: (20+ 1.5 ms)
9.Output protection: Fully defibrillator protected and isolated
Defibrillator | 1.Waveform: Biphasic(BTE) 2.Recharge Time: Less than 7 seconds with a new, fully charged 3.battery. 4.Energy display: Monitor display shows both selected and delivered energy. 5.Type of charging prompts: Voice and visual prompts. 6.Electrode impedance measurement range: 0-250 ohms. |
ECG Monitoring | 1.Patient connection:3-lead ECG cable or 5-lead ECG cable paddles. 2.Lead selection: Display on monitor paddles I II III AVR AVL AVF V. 3.ECG size: 0.25 0.5 1 1.5 2 4 cm/mV displayed on the monitor. 4.Heart rate: 20-300 BPM. 5.Heart rate alarm: display on monitor on/off, user selectable. 6.Smart alarms: beep/voice announcements indicate shockable rhythms. |
Battery | 1.Type: rechargeable Ni MH battery 12V. 2.Operating time: for a new, fully charged battery: 3.60 defibrillator discharges at maximum energy or 4.at least 3 hours of continuous ECG monitoring. 5.Other parameters affect operating time for various functions. |
Packing:
package size:49*54*49cm
weight: 10.5kg
Shandong Rayman Medical Systems Co.,Ltd.
Rayman medical system,As a world-renowned professional medical equipment manufacturer with more than 20 years production experience in China, Rayman is devoting to integrate R&D, production, sales and service of all kinds of medical equipments.
Rayman in 3 categories cover more than 30 series total 300+ basic models and items include patient monitors, ECG, ultrasound machine, Endoscope, laryngoscope, X-Ray, syringe pumps, infusion pumps, AED, fetal monitor, hospital beds,hospital trolley carts,wheelchairs, ect. ,which are exported to more than 150 countries all over the world.
Rayman has two R&D centers with a R&D team of more than 60 personnel. At present we have nearly 200 patents and authorized trademarks. Rayman also has three production bases cover an area of 50000 square meters equipped with independent laboratories, testing centers, professional intelligent SMT production lines, dust-free workshops, precision mold processing and injection molding factories, forming a complete and cost-controllable production and quality control system. The output is nearly 20 million units to meet the customized needs of global customers.
1.Who are we?
We are a company specializing in patient monitors, ECG, ultrasound machine, Endoscope, laryngoscope, X-Ray, syringe pumps, infusion pumps, AED, fetal monitor, hospital beds,hospital trolley carts,wheelchairs, ect.
2. How can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment.
3. Why should you buy from us not from other suppliers?
We Rayman is in the medical products field for more than 20 years.
4. What services can we provide?
Delivery Terms: FOB,CFR,CIF,EXW,DDP Payment Currency:USD,EUR
Payment Terms: T/T,L/C,D/P D/A,MoneyGram,Credit Card,PayPal,Western Union,Cash,Escrow.