Basic Info.
Model NO.
YJ-D9000
Model
Yj-D9000
Application
ICU
Display
7 Inches High-Resolution Display
SpO2 Module Measurement Range
30~100%
Waveform
Biphasic
Color
Blue
Feature
Aid Device
Transport Package
Corton
Specification
490*340*460
Trademark
FORERMED
Origin
China
HS Code
8419200000
Production Capacity
3000pieces/Year
Product Description
YJ-D9000 Defibrillator Monitor
YJ-D9000 is a professional biphasic defibrillator-monitor suitable
* Compact Durable* Light weighted defibrillator
* Multi-parameter Patient Monitor Manual defibrillation
* Automated External Defibrillalator(AED) pacer (option)
* 5 Lanquages to choose
SpO2 Module (Options)
1.Measurement Range: 30~100% +2% ;between 80%~90% others +5%
2.Alarm : User set high and low limit.
3.Alarm Accuracy: t10% within
2.Alarm : User set high and low limit.
3.Alarm Accuracy: t10% within
setting value Alarm time
4.Accuracy: less than 12 sec.
4.Accuracy: less than 12 sec.
5.Mieditech Pulse Oximeter
ECG Monitoring
1.3-lead ECG cable or 5-lead ECG cable
2.Display: I II AVR AVL AVF V.
3.ECG Size: 0.25 0.5 1 1.5 2 4 cm/mV
4.Heart Rate: 20-300GPM
1.3-lead ECG cable or 5-lead ECG cable
2.Display: I II AVR AVL AVF V.
3.ECG Size: 0.25 0.5 1 1.5 2 4 cm/mV
4.Heart Rate: 20-300GPM
Display
1.Screen Type: High-resolution display
2.Screen Size: 8 inch
3.Languages: 5toChoose
4.Sweep Speed: 25mm/sec
5.Information: Heart Rate.Lead/Pads.Alarm On/OffSp2AED Functions and Prompts Alarm
6.Selection and Limits Delivered Energy
7.5 Languages available: English.Russian. Spanish.Chinese.Turkish
Defibrillator
1.Waveform:Biphasic
2.Charge Time: Less than 7 seconds with a new fully charged battery.
3.Energy Display: Monitor display indicates both selected and delivered energy Charge Prompt
4.Type: Voice and visual prompts.
5.Electrode Impedance Measurement Range:0-250ohms
EGG Monitoring
1.Patient Connection: 3-lead ECG cable or 5-lead ECG cable paddles.
2.Lead Selection: Displayed on monitor paddles I II AVR AVL AVF V
3.ECG Size: 0.25 0.5 1 1.5 2 4 cm/mV display on monitor.
4.Heart Rate:20-300BPM.
5.Heart Rate Alarm: On/Off displayed on monitor user-selectable
6.Smart Alarms: Beeper/voice prompts indicate shock able rhythm.
SP02 Module [Options]
1.Measurement Range:30~100%+2% between 80%~90% others±5%
2.Alarm Range: User set high limit and low limit.
3.Alarm Accuracy:+10% within setting values.
4.Alarm time Accuracy: less than 12 sec.
5.1-Meditech Pulse Oximeter
2.Alarm Range: User set high limit and low limit.
3.Alarm Accuracy:+10% within setting values.
4.Alarm time Accuracy: less than 12 sec.
5.1-Meditech Pulse Oximeter
Recorder
1.Paper: 50mm thermal.
2.Speed: 12.5mm/sec25mm/sec50mm/sec. User-selectable 6-second delay
3.Printing Method: High-resolution thermal print head.
4.Print-out Modes: Manual or automatic user-configurable. 5.On/Off Control: Front panel and paddle.
6.Automatic Function: 9-seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge.
AED Mode
1.AED Function: Auto analyze and charge x3 with
1.AED Function: Auto analyze and charge x3 with
programmable auto energy level selection screen prompts and voice prompts.
2.Shockable Rhythms: Ventricular fibrillation with amplitude >=200uVventricular tachvcardia with rates >=140bpm and ORScomplex wave duration>=140ms
3.Charge Control: Control on device front panel press key on paddle
4.Prompts: Voice and visual prompts.
2.Shockable Rhythms: Ventricular fibrillation with amplitude >=200uVventricular tachvcardia with rates >=140bpm and ORScomplex wave duration>=140ms
3.Charge Control: Control on device front panel press key on paddle
4.Prompts: Voice and visual prompts.
Technical specifications | |||
Display | Screen Type | High-resolution display | |
Screen Size | 8 inches diagonally | ||
Sweep Speed | 25mm/sec | ||
Information | Heart Rate, Lead/Pads, Alarm On/Off, SpO2, AED | ||
Defibrillator | Waveform | Biphasic | |
Charge Time | Less than 7 seconds with a new fully charged battery. | ||
Energy Display | Monitor display indicates both selected and delivered energy. | ||
Charge Prompt Type | Voice and visual prompts. | ||
Electrode Impedance Measurement Range | 0- 250 ohms | ||
ECG Monitoring | Patient Connection | 3-lead ECG cable, or 5- lead ECG cable, paddles | |
Lead Selection | Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V. | ||
ECG Size | 0.25, 0.5, 1, 1.5, 2, 4 cm/mV display on monitor. | ||
Heart Rate | 20-300BPM | ||
Heart Rate Alarm | On/Off displayed on monitor, user-selectable | ||
Smart Alarms | Beeper/voice prompts indicate shock able rhythm | ||
Battery | Type | Rechargeable, Ni- MH battery, 12V | |
Operating Time | For a new, fully charged battery: 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring. Additional parameters will affect operating time with different functions. | ||
SpO2 Module | Measurement Range | 30~100%, ±2% between 80%~90%, others ±5% | |
Alarm Range | User set high limit and low limit | ||
Alarm Accuracy | ±10% within setting values | ||
Alarm time Accuracy | less than 12 sec |