Basic Info.
Model NO.
CCO-ES2PK
Specification
optional
Trademark
Comcernmed
Origin
China
Product Description
Hospital Equipment Medical Electrosurgery Surgical Unit Generator Multiple Working Modes electrosurgical units
We CONCERNMED make one-stop shopping hospital medical equipment:
Model: CCO-ES2PK
CCO-ES2PK is a Multifunctional electrosurgical generator with a wide range of application departments and a very high cost performance. It uses a new generation of tissue density instant feedback technology, which can automatically adjust the output power according to the change in tissue density. The surgeon brings convenience and reduces surgical damage, and is particularly suitable for surgical applications such as general surgery, orthopedic surgery, gynecological surgery, ENT surgery, neurosurgery, skin plastic surgery, oral and maxillofacial surgery.
Monopolar modes- monopolar coagulation
Monopolar coagulation mode includes spray coagulation, forced coagulation and soft coagulation, and the output power is adjustable
spray coagulation: high-efficiency coagulation without contact surface. The coagulation depth is shallow. The tissue
is removed by evaporation. It usually use a Blade or ball electrode for coagulation.
forced coagulation: It's non-contact coagulation. The output threshold voltage is lower than spray coagulation. It's
suitable for coagulation in a small area.
soft coagulation: Mild coagulation penetrates deeply to prevent tissue carbonization and reduce electrode adhesion to tissue.
Bipolar mode
The bipolar mode includes standard mode and fine mode. The output power is adjustable.
Standard mode: It's suitable for most bipolar applications. Keep the low voltage to prevent sparks.
Fine mode: It's used for high precision and fine control of drying amount. Keep the low voltage to prevent sparks.
3 monopolar cutting modes: pure cut, blend 1, blend 2
3 monopolar coagulation modes: spray coagulation, forced coagulation, and soft coagulation
2 bipolar output modes: standard and fine
CQM contact quality monitoring system
Electrosurgical pens and foot switch control
Start with the recently used mode, power and other parameters
Volume adjustment function;
Cut and coagulate in an intermittent manner.
3 monopolar coagulation modes: spray coagulation, forced coagulation, and soft coagulation
2 bipolar output modes: standard and fine
CQM contact quality monitoring system
Electrosurgical pens and foot switch control
Start with the recently used mode, power and other parameters
Volume adjustment function;
Cut and coagulate in an intermittent manner.
Monopolar mode- Monopolar cutting
3 monopolar cutting modes includes pure cut, blend 1and blend 2. The output power is adjustable.
Pure cut: cut the tissue cleanly and accurately without coagulation
blend 1: Use when the cutting speed is slightly slow and a small amount of hemostasis is required.
blend 2: Compared with blend 1, it is used when the cutting speed is slightly slower and the better hemostatic effect is needed.
3 monopolar cutting modes includes pure cut, blend 1and blend 2. The output power is adjustable.
Pure cut: cut the tissue cleanly and accurately without coagulation
blend 1: Use when the cutting speed is slightly slow and a small amount of hemostasis is required.
blend 2: Compared with blend 1, it is used when the cutting speed is slightly slower and the better hemostatic effect is needed.
Monopolar modes- monopolar coagulation
Monopolar coagulation mode includes spray coagulation, forced coagulation and soft coagulation, and the output power is adjustable
spray coagulation: high-efficiency coagulation without contact surface. The coagulation depth is shallow. The tissue
is removed by evaporation. It usually use a Blade or ball electrode for coagulation.
forced coagulation: It's non-contact coagulation. The output threshold voltage is lower than spray coagulation. It's
suitable for coagulation in a small area.
soft coagulation: Mild coagulation penetrates deeply to prevent tissue carbonization and reduce electrode adhesion to tissue.
Bipolar mode
The bipolar mode includes standard mode and fine mode. The output power is adjustable.
Standard mode: It's suitable for most bipolar applications. Keep the low voltage to prevent sparks.
Fine mode: It's used for high precision and fine control of drying amount. Keep the low voltage to prevent sparks.
one-stop shopping hospital medical equipment | x ray room | x ray machine |
processor | ||
x ray film | ||
cassette | ||
Intensifying screen | ||
lead clothings(lead glove, lead glasses, lead cap, lead apron, lead collar) | ||
ultrasound | b/w 2D ultrasound | |
2/3/4D color ultrasound | ||
laboratory room | chemistry analyzer | |
hematology analyzer | ||
microplate elisa reader | ||
microplate washer | ||
centrifuge | ||
pipette | ||
water bath | ||
urine analyzer | ||
operation room | anesthesia machine | |
ventilator | ||
operating lamp | ||
operation table | ||
pendant | ||
medical drill and saw | ||
ECG | ||
patient monitor | ||
defibrillator | ||
infusion pump | ||
electrocoagulation | ||
oxygen generator | ||
electric suction device | ||
autoclave sterilizer | ||
ect. |