Basic Info.
Model NO.
XR210116001
Power Consumption
190W
Product Name
Patient Monitor
Warranty Period
2 Years
After-Sales Service
Whole Using Lifetime
Transport Package
Wooden Case
Specification
320mm*165mm*280mm
Trademark
XINDRAY MEDICAL
Origin
China
Production Capacity
10000
Product Description
Hospital Use Biphasic Defibrillator Monitor Machine
Certificate:
Package:
Shipping:
Our Service:
Features:
· 4-in-one design including: monitoring, Manual Defib, AED and pacer
· Power on within 2s, Charging to 200J within 3s, ECG recovery within 2.5s
· Up to 360J escalating dose energy to maximize defibrillation success
· Powerful power capacity with battery to support continuous long time monitoring and shocks during transport without external power supply
· Effective IT solution avoiding manual recording, improving efficiency and reducing the workload of clinical staff
Specifications:
· Power on within 2s, Charging to 200J within 3s, ECG recovery within 2.5s
· Up to 360J escalating dose energy to maximize defibrillation success
· Powerful power capacity with battery to support continuous long time monitoring and shocks during transport without external power supply
· Effective IT solution avoiding manual recording, improving efficiency and reducing the workload of clinical staff
Specifications:
Physical | Dimensions: Without external paddles: 295mm (w)x 218 mm (d) x 279 mm (h) With external paddles: 295 mm (w) x 218 mm (d)x323 mm (h) Weight: Main unit: 5.6 kg (including ECG/ defibrillator/ pacing/5pO/ 2Temp/ Resp) Battery package (each): 0.75 kg External paddle sets: 0.8 kg |
Environmental and Physical Requirements | Water Resistance: IPX4 (without external power) Solids Resistance: IP4X Temperature: Operating: 0 to 45ºC (Microstream CO2:0 to 40ºC; Sidestream CO2: 5to 35°C) (at least 60 minutes of working time when the temperature reduces from room temperature to -20ºC) Humidity: Operating/Storage: 10 to 95%, non-condensation Altitude: Operating/ Storage: -381m to+4575m Shock and Vibration: Comply the requirements of21.102, IS09919 (Shock and vibration for transport} Bump: Comply the requirements of 6.3.4.2, EN1789(Medical devices for use in road ambulances) Free fall: : Comply the requirements of 6.3.4.3, EN1789 (Height of fall: 0.75 m) EMC: Comply IEC60601-1-2 Safety: Comply EN/IEC 60601-1 |
Display | Type: TFT Color LCD Dimensions: 8.4inch Resolution: 800x600 pixels Display Waveforms: Max.4 channels Wave Viewing Time: Max.16s (ECG) |
Power | AC Power Line voltage: 100 to 240V~(±10%) Current: 1.8 to 0.8A Frequency: 50/60 Hz (±3 Hz) DC Power (through DC-AC Inverter) Input voltage: 12VDC Power Consumption: 190W Battery Type: 4.5 Ah, 14.8V, recharge able lithium ion battery pack Number: Max.2 Charge time: 2 hours to 90% and 3 hours to 100% with device off Capacity Indicator: 5-segment led indicator for fast battery capacity evaluation Capacity(Two new, fully charged bttery): Monitoring Mode: ≥10hours, Without recording, typical ECG monitoring, LCD brightness set to 1 Defib Mode: 200 times, 360J discharge at intervals of 1 minute without recording Pacing Mode: 6 hours, 50Ohm load im pedance, Pacing rate: 80bpm, Pacing output: 60mA |
Defibrillator | Wavefom: Biphasic truncated exponential waveform (BTE) with impedance compensation Energy accuracy: ±2Jor 15% of setting, whichever is greater, into 50 Ohm Charge Time: Less than 5 seconds to 200Joules with a new, fully charged battery Less than 8 seconds to 360Joules with a new, fully charged battery Shock Delivery: Via multifunction defib electrode pads, or paddles Patient Impedance Range: 20 to 200 Ohm (External defibrillation) Manual Mode Output Energy: 1,234,5.6,7,8,9,10,15,20,30,50,70,100,150, 170,200,300,360J Synchronous Cardioversion: Energy transfer begins within 60ms of the QRS peak Energy transfer begins within 25ms of the External 5ync Pulse AED Mode Output Energy: Userselectable AED Shock Series: Energy level: 100 to 360 J, selectable Shocks series:1, 2, 3, selectable Default configuration meets 2010 AHA Guidelines 5ensitivity and Specificity: Meets AAMI DF -80 |
Noninvasive Pacing | Waveform: Mono phasic square wave pulse Pulse Width: 20 ms, ±5% Refractory period: 200to 300 ms, ±3% (function of rate) Pacing Mode: Demand or fixed Pacing rate: 40 ppm to 170ppm, ±1.5% Pacing output: 0 mA to 200 mA, ±5% or 5mA, whichever is greater 4:1 pacing: Pacing pulse frequency reduced by factor of 4 when activated |
ECG Monitoring | Lead type: 3 leads ECG, 5leads ECG, 12leads ECG PADS/ PADDLES Lead Selection: 3Head:l, ll, lll 5-lead: l, ll, lll, aVR, aVL, aVFV 12-lead: l, ll, lll, aVR, aVL, aVF, V1 to V6 Pads/Paddles HeartRate Display: Adult: 15 to300 bpm Pediatric: 15 to 350 bpm Neonate: 15 to 350bpm Resolution: 1 bpm Arrhymia: Yes Alarms: Yes ECG size: 2.5mm/mV(x0.25), 5mm/mV(x0.5), 10 mm/mV(x 1), 20 mm/mV(x2), 40m m/mW(x4) Sweep speed: 6.25mm/s, 12.5 mm/s, 25 mm/s, 50mm/s Patient Isolation (defibrillation proof): Type CR: EG, RESP, TEMP, SpO2, NIBP, IBP Type BF: CO2 and external defib |
Respiration | Technique: Trans thoracic impedance Range: Adult:0 to 120 rpm Pediatric, neonate:0 to 150 rpm Resolution: 1rpm. |
Spo2, Pulse Oximetry | SpO2 Range: 0 to 100% Resolution: 1% PR Range: 20 to 254 bpm Masimo SpO2 Range: 1to100%. Resolution: 1% PR Range: 25 to 240bpm. Nellcor SpO2 Range: 0 to 100% Resolution: 1% PR Range: 20 to 300 bpm |