Hospital Use Biphasic Defibrillator Monitor Machine

Classification: Imaging Diagnostic Equipment
Type: Ultrasound Scanner
Certification: CE, ISO13485
Line Voltage: 100 to 240V~(±10%)
Current: 1.8 to 0.8A
Frequency: 50/60 Hz (±3 Hz)

Products Details

Basic Info.

Model NO.
XR210116001
Power Consumption
190W
Product Name
Patient Monitor
Warranty Period
2 Years
After-Sales Service
Whole Using Lifetime
Transport Package
Wooden Case
Specification
320mm*165mm*280mm
Trademark
XINDRAY MEDICAL
Origin
China
Production Capacity
10000

Product Description

Hospital Use Biphasic Defibrillator Monitor Machine        
Hospital Use Biphasic Defibrillator Monitor Machine

Features:

· 4-in-one design including: monitoring, Manual Defib, AED and pacer
· Power on within 2s, Charging to 200J within 3s, ECG recovery within 2.5s
· Up to 360J escalating dose energy to maximize defibrillation success
· Powerful power capacity with battery to support continuous long time monitoring and shocks during transport without external power supply
· Effective IT solution avoiding manual recording, improving efficiency and reducing the workload of clinical staff

Specifications:
 
Physical Dimensions:
Without external paddles: 295mm (w)x 218 mm (d) x 279 mm (h)
With external paddles: 295 mm (w) x 218 mm (d)x323 mm (h)
Weight:
Main unit:
5.6 kg (including ECG/ defibrillator/ pacing/5pO/ 2Temp/ Resp)
Battery package (each): 0.75 kg
External paddle sets: 0.8 kg
Environmental and Physical Requirements Water Resistance: IPX4 (without external power)
Solids Resistance: IP4X
Temperature:
Operating: 0 to 45ºC (Microstream CO2:0 to 40ºC; Sidestream CO2: 5to 35°C)
(at least 60 minutes of working time when the temperature reduces from room temperature to -20ºC)
Humidity:
Operating/Storage: 10 to 95%, non-condensation
Altitude: Operating/ Storage: -381m to+4575m
Shock and Vibration:
Comply the requirements of21.102, IS09919 (Shock and vibration for transport}
Bump:
Comply the requirements of 6.3.4.2, EN1789(Medical devices for use in road ambulances)
Free fall: :
Comply the requirements of 6.3.4.3, EN1789 (Height of fall: 0.75 m)
EMC:
Comply IEC60601-1-2
Safety:
Comply EN/IEC 60601-1
Display Type: TFT Color LCD
Dimensions: 8.4inch
Resolution: 800x600 pixels
Display Waveforms: Max.4 channels
Wave Viewing Time: Max.16s (ECG)
Power AC Power
Line voltage: 100 to 240V~(±10%)
Current: 1.8 to 0.8A
Frequency: 50/60 Hz (±3 Hz)
DC Power (through DC-AC Inverter)
Input voltage: 12VDC
Power Consumption: 190W
Battery
Type: 4.5 Ah, 14.8V, recharge able lithium ion battery pack
Number: Max.2
Charge time: 2 hours to 90% and 3 hours to 100% with device off
Capacity Indicator:
5-segment led indicator for fast battery capacity evaluation
Capacity(Two new, fully charged bttery):
Monitoring Mode: ≥10hours, Without recording, typical ECG monitoring, LCD brightness set to 1
Defib Mode: 200 times, 360J discharge at intervals of 1 minute without recording
Pacing Mode: 6 hours, 50Ohm load im pedance, Pacing rate: 80bpm, Pacing output: 60mA
Defibrillator Wavefom:
Biphasic truncated exponential waveform (BTE) with impedance compensation
Energy accuracy:
±2Jor 15% of setting, whichever is greater, into 50 Ohm
Charge Time:
Less than 5 seconds to 200Joules with a new, fully charged battery
Less than 8 seconds to 360Joules with a new, fully charged battery
Shock Delivery:
Via multifunction defib electrode pads, or paddles
Patient Impedance Range:
20 to 200 Ohm (External defibrillation)
Manual Mode
Output Energy:
1,234,5.6,7,8,9,10,15,20,30,50,70,100,150, 170,200,300,360J
Synchronous Cardioversion: Energy transfer begins within 60ms of the QRS peak
Energy transfer begins within 25ms of the External 5ync Pulse
AED Mode
Output Energy: Userselectable
AED Shock Series:
Energy level: 100 to 360 J, selectable
Shocks series:1, 2, 3, selectable
Default configuration meets 2010 AHA Guidelines
5ensitivity and Specificity: Meets AAMI DF -80
Noninvasive Pacing Waveform: Mono phasic square wave pulse
Pulse Width: 20 ms, ±5%
Refractory period:
200to 300 ms, ±3% (function of rate)
Pacing Mode: Demand or fixed
Pacing rate: 40 ppm to 170ppm, ±1.5%
Pacing output:
0 mA to 200 mA, ±5% or 5mA, whichever is greater
4:1 pacing:
Pacing pulse frequency reduced by factor of 4 when activated

 
ECG Monitoring
 
Lead type:
3 leads ECG, 5leads ECG, 12leads ECG PADS/ PADDLES
Lead Selection:
3Head:l, ll, lll
5-lead: l, ll, lll, aVR, aVL, aVFV
12-lead: l, ll, lll, aVR, aVL, aVF, V1 to V6
Pads/Paddles
HeartRate Display:
Adult: 15 to300 bpm
Pediatric: 15 to 350 bpm
Neonate: 15 to 350bpm
Resolution: 1 bpm
Arrhymia: Yes
Alarms: Yes
ECG size:
2.5mm/mV(x0.25), 5mm/mV(x0.5), 10 mm/mV(x 1), 20 mm/mV(x2), 40m m/mW(x4)
Sweep speed:
6.25mm/s, 12.5 mm/s, 25 mm/s, 50mm/s
Patient Isolation (defibrillation proof):
Type CR: EG, RESP, TEMP, SpO2, NIBP, IBP
Type BF: CO2 and external defib
Respiration
 
Technique: Trans thoracic impedance
Range:
Adult:0 to 120 rpm
Pediatric, neonate:0 to 150 rpm
Resolution: 1rpm.
Spo2, Pulse Oximetry
 
SpO2
Range: 0 to 100%
Resolution: 1%
PR Range: 20 to 254 bpm
Masimo SpO2
Range: 1to100%.
Resolution: 1%
PR Range: 25 to 240bpm.
Nellcor SpO2
Range: 0 to 100%
Resolution: 1%
PR Range: 20 to 300 bpm
 


 
Hospital Use Biphasic Defibrillator Monitor MachineHospital Use Biphasic Defibrillator Monitor MachineHospital Use Biphasic Defibrillator Monitor MachineHospital Use Biphasic Defibrillator Monitor MachineHospital Use Biphasic Defibrillator Monitor MachineHospital Use Biphasic Defibrillator Monitor Machine
Certificate:
Hospital Use Biphasic Defibrillator Monitor Machine

Package:
Hospital Use Biphasic Defibrillator Monitor Machine

Shipping:
Hospital Use Biphasic Defibrillator Monitor Machine

Our Service:
Hospital Use Biphasic Defibrillator Monitor Machine
Hospital Use Biphasic Defibrillator Monitor Machine



 