Basic Info.
Model NO.
YJ-F6
Battery
Rechargeable Lithium Battery: 12V/2200mAh
Alarm
Three-Level Acousto-Optic Alarm
Transport Package
Carton
Specification
490*340*460
Trademark
FORERMED
Origin
China
Production Capacity
10000
Product Description
YJ-F6 Medical Device First-Aid Beside Cardiac ECG Portable Patient Monitor
Features:
- 12.1'' color TFT LED screen supports display Max.8 waveforms
- Suitable for monitoring adult, pediatric and neonatal patient
- Designed without fan, characterized with no noise and lower consumption
- Acoustic and visual alarm
- Analog SpO2 technology, against interference of ESU, motion & low infusion
- Display mode: Standard, Large Font, Trend Table, Full lead ECG, Oxy CRG
- Drug calculation and titration table
- Pacemaker detection and Arrhythmia analysis
- Supporting large capacity of storage
- Isolated against defibrillation effect
Standard Configuration:
3-lead or 5-lead ECG/HR, RESP, Dual TEMP, SpO2/PR, NIBP
Optional Configuration:
2 IBP, Central Monitoring System, Touch screen, Printer, Trolley, Wall-mount
3-lead or 5-lead ECG/HR, RESP, Dual TEMP, SpO2/PR, NIBP
Optional Configuration:
2 IBP, Central Monitoring System, Touch screen, Printer, Trolley, Wall-mount
Specification:
ECG | Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V Gain: 2.5mm/mV(×0.25), 5.0mm/mV(×0.5), 10mm/mV (×1), 20mm/mV (×2), 40 mm/ mV (×4), Auto Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50 mm/s ECG signal range: ±12 mV (Gain × 0.25) Auto ECG signal range: ±6 mV Accuracy: ±1bpm/ ±1%, whichever is greater Resolution: 1 bpm |
RESP | Method: Impedance between RA-LL, RA-LA Gain: ×0.25, ×0.50, ×1, ×2 Respiration Rate: Adult: 0 ~ 120 BrPM; Neonatal / Pediatric: 0 ~ 150 BrPM Resolution: 1 BrPM Accuracy: ±2 bpm or ±2%, whichever is greater Apnea Alarm: 10 ~ 40 s |
NIBP | Method: Oscillometric Measure mode: Manual, Auto, STAT STAT mode cycle time: Keep 5 minutes, at 5 seconds interval Measure and Alarm Range: Adult:SYS: 40 ~ 280 mmHg,DIA: 10 ~ 220 mmHg ,MEAN: 20 ~ 240 mmHg Static pressure accuracy: ±3mmHg Resolution: 1mmHg Accuracy: Maximum Mean error ±5mmHg Maximum Standard deviation ≤8mmHg Over pressure Protection: Dual protection via software & hardware |
SPO2 | Measurement Range: 0 ~ 100 % Resolution: 1 % Accuracy: 70% ~ 100%: ±2 % 40% ~ 69%, ±3 %; <39%, unspecified; |
TEMP | Channel: Dual-Channel, provide T1; T2; ΔT Measuring and Alarm Range: 0.0 ºC~ 50 ºC (32ºF~ 122ºF) Resolution: 0.1ºCor 1ºF Accuracy: ±0.1ºC(exclusive probe error) |
PR | Measuring and Alarm Range: 20~300bpm Accuracy: ±3bpm Resolution: 1bpm |