Basic Info.
Model NO.
THR-MD-800B
Display
7′′ Diagonal High Resolution True-Color Graphic Le
Standard Parameter
ECG/ Resp/Defibrillator
Optional Parameter
Recorder
Warranty
18month
OEM
Available
Transport Package
Standard Export Packing
Specification
CE and ISO
Trademark
THR
Origin
China
Production Capacity
100 Pieces Per Week
Product Description
Automatic Portable Cardiac Defibrillator Machine(THR-MD-800B)
ECG
ECG lead: I, II, III, Avr, Avl, Avf, V1~V6
S-T segment analysis: -2.0~2.0mv
Protegtion: Withstand 4000vAc/50Hz voltage in isolation and work against eletrosurgical interence and defibrillation
ECG lead/cable: General lead/cable for adult, pediatric and neonatal patients
NIBP
Method: Automatic oscillation
Working mode: Manual/Automaic
Measurement range: Adult 10~250mmHg
Pediatric10~250mmHg
Neonatal 10~135mmHg
Temperature(TEMP)
Measurement range: 20~45° C
Resoluion: 0.1° C
Respiration(RESP)
Measurement method thoracic impedance
Spo2
Display: Spo2 value, pulse histongram, waveform, Pulse
Range: 0~99%for adult, pediatric and neonatal patients
Probe: Standard adult finger clip
Optional pediatric Y-type clip and neonatal wrap
Pulse
Pulse range: 0~300bpm
Pulse accuracy: ± 2bpm
Defibrillator
Non-synchronizer: Outlife difibrillator
Sine wave: Monophasic technology
Energy: 0, 20, 50, 100, 160, 250, 300, 360 joule
Charging time: At 360J less than 10 sec
Paddle options: Reusable extermal adult paddles(pediatric paddles integrated)
Power
Operates from the mains(AC)and with its intemal NIMH battery
More Pictures:
ECG
ECG lead: I, II, III, Avr, Avl, Avf, V1~V6
S-T segment analysis: -2.0~2.0mv
Protegtion: Withstand 4000vAc/50Hz voltage in isolation and work against eletrosurgical interence and defibrillation
ECG lead/cable: General lead/cable for adult, pediatric and neonatal patients
NIBP
Method: Automatic oscillation
Working mode: Manual/Automaic
Measurement range: Adult 10~250mmHg
Pediatric10~250mmHg
Neonatal 10~135mmHg
Temperature(TEMP)
Measurement range: 20~45° C
Resoluion: 0.1° C
Respiration(RESP)
Measurement method thoracic impedance
Spo2
Display: Spo2 value, pulse histongram, waveform, Pulse
Range: 0~99%for adult, pediatric and neonatal patients
Probe: Standard adult finger clip
Optional pediatric Y-type clip and neonatal wrap
Pulse
Pulse range: 0~300bpm
Pulse accuracy: ± 2bpm
Defibrillator
Non-synchronizer: Outlife difibrillator
Sine wave: Monophasic technology
Energy: 0, 20, 50, 100, 160, 250, 300, 360 joule
Charging time: At 360J less than 10 sec
Paddle options: Reusable extermal adult paddles(pediatric paddles integrated)
Power
Operates from the mains(AC)and with its intemal NIMH battery