- Overview
- Product Description
- Product Specification
- Packaging & Shipping
- Certifications
- Company Profile
- FAQ
Basic Info.
Product Description
An automated external defibrillator or automatic electronic defibrillator (AED) is a portable electronic device that automatically diagnoses the life-threatening cardiac arrhythmias of ventricular fibrillation (VF) and pulseless ventricular tachycardia, and is able to treat them through defibrillation, the application of electricity which stops the arrhythmia, allowing the heart to re-establish an effective rhythm.
AED devices are usually small and lightweight, making them easy to carry to various public where cardiac arrest may occur.
2.Simple operation:
Non-professionals who have received simple training can also operate it. The device has clear voice prompts and an intuitive operation interface to guide users to complete the first aid steps step by step.
3.Intelligent analysis:
It can automatically analyze the patient's electrocardiogram and quickly and accurately determine whether electric shock defibrillation is needed.
4.High safety:
Electric shock will only be released when a shockable heart rhythm is detected, reducing the risk of secondary injury to the patient due to misoperation.
Operating Step:
1. Turn on: Place the AED next to the patient and operate on the patient's side. To turn on the AED, press the power switch or open the cover of the display. The instrument will give a voice prompt to guide the next steps.
2. Paste: Place the electrode pads.
1) Adult electrode pad placement: According to the diagram on the AED electrode pad, stick one electrode pad on the upper right side of the patient's exposed chest and the other electrode pad on the outside of the patient's left nipple.
2) Infant and child electrode pad placement: Stick the two electrode pads on the center of the chest and the left shoulder blade behind the infant and child respectively. Larger children can also place the electrode pads in the same position as adults.
3. Plug: Insert the electrode pad plug into the AED host jack, and the AED will automatically analyze the heart rate. At this time, emergency personnel and bystanders should ensure that they do not come into contact with the patient to avoid affecting the instrument's analysis of the heart rate. Heart rhythm analysis takes 5 to 15 seconds.
4. Charge: When the AED analyzes a heart rhythm that requires defibrillation, the capacitor will often charge automatically, and there will be a sound or indicator light prompt. Before pressing the "shock" button, make sure that no one is touching the patient. After the first shock, immediately continue cardiopulmonary resuscitation (CPR).
WHY USE AED Defibrillator?
Automated External Defibrillator: To understand AED, we must first understand the cardiac arrest. Cardiac arrest refers to the sudden termination of the heart's ejaculation function.efibrillator monitor for emergency
1.Easy to operate:
AED is designed to be easy for non-professional medical personnel to operate. It has clear voice prompts and an intuitive operation interface that can guide users step by step through the defibrillation process.
2.Quick response:
For patients with sudden cardiac arrest, every second is critical. AED can quickly analyze the patient's heart rhythm and quickly release electric shock when necessary to buy precious rescue time.
3. Improve survival rate:
Studies have shown that using AED within a few minutes of cardiac arrest can greatly increase the patient's chance of survival.
4. Wide applicability:
AED is suitable for patients of all ages and different health conditions. As long as there is a defibrillable arrhythmia, they may benefit from it.
1. Standard Four buttons: On/Off, Shock,Adult/child, CPR
2. Visual Prompts: LED prompts;Automatic Self-test
3. Built non-rechargeable Battery: 2.8 Ah
4. The Maximum Voltage: 1400±50V
Portable Automatic External AED defibrillator monitor for emergency
5. Output disabled when the patient impedance is outside limits 20Ω to 200Ω
6. 120 discharges at 200 Joules
7.Shelf Life (25°C+15C): 3 years standby (after installation)
Product Name | AED Defibrillator |
Output | Biphasic truncated exponential |
Energy Sequence(child) | 50J,50J.50J |
Energy Sequence(Adult) | 150J,200J,200J |
Charge Time | 6 sec. to 150J8 sec. to 200 J(New battery) |
Analysis Time | 6 sec |
Preparation time | The maximum time from the initiation of rhythm analy-sis to readiness for discharge with a new battery. Less than 10 seconds. The maximum time from the initiation of rhythm analy-sis to readiness for discharge after 6 shocks Less than 10 seconds The maximum time from initially switching power on to readiness for discharge. Less than18 seconds. |
Visual Prompts | LED prompts; Automatic Self-test |
Controls Four buttons | On/Off, Shock,Adult/child,CPR |
Output Energy Accuracy | +10% into any impedance from 25 to 175Q |
The Maximum Voltage | 1400+50V Output disabled when the patient impedance is outside limits 202 to 2002 |
Battery | Index: Content Part No: CR123A-4x2 Non-rechargeable: 2.8 Ah Capacity: 120 discharges at 200 Joules Shelf Life: (25°C+15C)5 years standby (after installation) |
Physical | 1.Operating Temperature: 0° to 40°C 2.Operating Humidity: Relative humidity between 30% and 95%(non-condensing) 3.Storage Temperature(without battery): -20°C to 55°C 4.Storage Humidity(without battery): Up to 93%(non-condensing) |
Packing:
package size:33*16.5*36cm
weight 3.2kg
4 unit per carton
ackage size: 71*35*38.5cm
otal gross weight 14 KG
Shandong Rayman Medical Systems Co.,Ltd.
Rayman medical system,As a world-renowned professional medical equipment manufacturer with more than 20 years production experience in China, Rayman is devoting to integrate R&D, production, sales and service of all kinds of medical equipments.
Rayman in 3 categories cover more than 30 series total 300+ basic models and items include patient monitors, ECG, ultrasound machine, Endoscope, laryngoscope, X-Ray, syringe pumps, infusion pumps, AED, fetal monitor, hospital beds,hospital trolley carts,wheelchairs, ect. ,which are exported to more than 150 countries all over the world.
Rayman has two R&D centers with a R&D team of more than 60 personnel. At present we have nearly 200 patents and authorized trademarks. Rayman also has three production bases cover an area of 50000 square meters equipped with independent laboratories, testing centers, professional intelligent SMT production lines, dust-free workshops, precision mold processing and injection molding factories, forming a complete and cost-controllable production and quality control system. The output is nearly 20 million units to meet the customized needs of global customers.
1.Who are we?
We are a company specializing in patient monitors, ECG, ultrasound machine, Endoscope, laryngoscope, X-Ray, syringe pumps, infusion pumps, AED, fetal monitor, hospital beds,hospital trolley carts,wheelchairs, ect.
2. How can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment.
3. Why should you buy from us not from other suppliers?
We Rayman is in the medical products field for more than 20 years.
4. What services can we provide?
Delivery Terms: FOB,CFR,CIF,EXW,DDP Payment Currency:USD,EUR
Payment Terms: T/T,L/C,D/P D/A,MoneyGram,Credit Card,PayPal,Western Union,Cash,Escrow.